Power Transmission
Spacer
Conductor Spacer (Spacer Damper) is a high-strength aluminum alloy fitting for bundled conductors (2-split, 4-split, 6-split, 8-split) in overhead transmission lines. It maintains fixed spacing between sub-conductors, prevents clashing, suppresses aeolian vibration, and reduces power loss—critical for 110kV–1000kV high-voltage networks.
Key Features
-
✅ High-Strength Aluminum Alloy: Lightweight, corrosion-resistant, 30 year service life
-
✅ Elastomer-Lined Jaws: EPDM rubber inserts protect conductors, no abrasion
-
✅ Vibration Damping Design: Integral damper reduces galloping & resonance fatigue
-
✅ High Slip Resistance: ≥5kN axial grip, no sliding under wind/ice loads
-
✅ Easy Bolted Installation: No special tools; field-adjustable spacing
-
✅ Wide Conductor Compatibility: Fits ACSR, AAAC, AAC (Ø15–50mm)
-
✅ Corrosion-Proof Hardware: Hot-dip galvanized bolts & stainless steel springs
Technical Specifications
- Model: FJQ-2, FJQ-4, FJZ-6, FJZ-8 (2/4/6/8-split)
- Material:
- Frame: 6061-T6 aluminum alloy (anodized)
- Jaws: Aluminum alloy EPDM rubber lining
- Bolts: Hot-dip galvanized steel (Grade 8.8)
- Conductor Range: Ø15–50mm (ACSR, AAAC, AAC)
- Split Configuration: 2-split, 4-split, 6-split, 8-split
- Spacing Distance: 300–1200mm (customizable)
- Slip Strength: ≥5kN (axial); ≥2.5kN (transverse)
- Working Temperature: -40°C to 90°C (continuous); 250°C (short-circuit)
- Standards: DL/T 1098, GB/T 2314, IEC 61897, IEEE 998
- Finish: Anodized aluminum (≥15μm); galvanized hardware
- Weight: 1.2–8.5kg (model-dependent)
Applications
-
110kV–1000kV overhead transmission lines
-
Bundled conductor systems (2/4/6/8-split)
-
ACSR, AAAC, AAC, and steel-reinforced conductors
-
Long-span river crossings & mountainous terrain lines
-
Coastal/desert/industrial polluted zones (anti-corrosion)
Product Specifications (Shopify Block)
-
Product Name: Conductor Spacer / Spacer Damper (FJQ/FJZ Type)
-
Model: FJQ-2, FJQ-4, FJZ-6, FJZ-8
-
Material: 6061-T6 Aluminum Alloy, EPDM Rubber, Galvanized Steel
-
Type: Bundled Conductor Spacer / Vibration Damper
-
Conductor Fit: ACSR, AAAC, AAC (Ø15–50mm)
-
Split Design: 2-split, 4-split, 6-split, 8-split
-
Voltage Rating: 110kV–1000kV
-
Standard: DL/T 1098, GB/T 2314, IEC 61897
-
Feature: Vibration Damping, Anti-Corrosion, Easy Install
-
Application: High-Voltage Transmission Bundled Conductors
Tags / Keywords
Conductor spacer, spacer damper, FJQ spacer, FJZ spacer, bundled conductor spacer, transmission line spacer, ACSR spacer, 4-split spacer, power line hardware, overhead line fitting
Collection / Category
-
Main Category: Power Line Hardware
-
Subcategory: Bundled Conductor Accessories
-
Optional: Vibration Control, High-Voltage Fittings